Image of Lil Tuna instrument

Lil' Tuna

The first fully automated, plate-based, benchtop buffer exchange system

Automated buffer exchange with plate-based throughput

Lil’ Tuna is the first automated, plate-based ultrafiltration and diafiltration (UF/DF) system for buffer exchanging, concentrating, or desalting proteins, viral vectors and nucleic acids - with consistently high recoveries. Process 1 to 96 samples in parallel with minimal hands-on time and achieve consistent and reliable sample prep for formulation screening, stability testing or any other downstream assay. Get brochure.

Plates or single samples: Run 96- or 24-well plates or 1-6 single samples. 

• Parallel processing with flexible volumes: 96-well plates can handle 100 – 450 µL while 24-well plates and single samples hold from 0.45 - 8 mL of each sample.

• Stellar recoveries: Get ≥96% of your sample back during buffer exchange or concentration. 

• Concentration with full process control: Concentrate samples with precise, automated final volume control. 

• Durable, low-binding consumables: Choose regenerated cellulose (RC) or polyethersulfone (PES) membranes – whichever works best for your sample.

• Hands-free operation: Load your samples, set up your run and let Lil’ Tuna handle the entire UF/DF process on its own.

• Automation-ready: Universal API software and robot-accessible sample stage let Lil’ Tuna seamlessly integrate.

Lil-Tuna_workflow

Want a quote?

Videos

Check out Lil' Tuna

Whatever floats your throughput boat

Whether you’re running a handful of samples or a massive formulation screen — Lil’ Tuna swims in your lane. Go big with Unfilter 96 or 24 plates for boatloads of samples or keep it light and run 1 to 6 Unas. You get your choice of membrane chemistries and molecular weight cutoffs to suit your sample — with recoveries ≥96%.

Whatever floats your throughput boat
Lil-Tuna_workflow

Just flow with it

Lil’ Tuna uses our tried-and-tested pressure-based UF/DF approach for buffer exchange. Each run starts with a check of the initial sample volume in each well using an ultrasonic volume sensor. Then samples are pressurized to send the filtrate through the membrane while gentle mixing keeps things evenly distributed and flowing smoothly. The volume gets checked again and Lil’ Tuna refills each well with your exchange buffer. This cycle repeats until your samples reach your target exchange percent and volume.

Dive deep on concentration

Sometimes samples need to be concentrated before they’re ready for downstream assays. Lil’ Tuna can take a liter of dilute sample and bring it down to 192 mL — or even lower with a subsequent concentration step.

Lil-Tuna_sample-concentration-buffering-graphic
Tackle thick exchanges

Tackle thick exchanges

High viscosity means longer buffer exchange times — but Lil’ Tuna has a fix for that. By adding exchange buffer before the first pressurization step, samples flow efficiently and viscosity stays in check throughout the run.

Swim through setup

Setting up a run on Lil’ Tuna is super simple. Quickly design your exchange in the software — set your target exchange percentage and volume, then click and drag samples and buffers into each well. The pipette guide shows you what to load where so there’s no guess work when handling multiple samples. Set your loaded plates or Unas on the stage, fill your buffer bottles, hit start, and Lil’ Tuna sets sail.

Swim through setup
Progress screen

Check your line

Check back whenever you want — Lil’ Tuna tracks exchange cycles completed, current filtration status, percent exchanged per sample, and estimated time remaining. If some samples finish early, pause the run to pull them out while the rest keep going. Either way, Lil’ Tuna tells you when it’s a wrap.

Sync up the whole school

Lil’ Tuna seamlessly integrates into your automated lab with API software, a sample stage designed for easy access and simple template import functions. Link up Lil’ Tuna to analytical tools and workflows solutions — Lil’ Tuna swims in perfect unison with any automation setup.

Lil' Tuna automation compatibility workflow

Tech

Learn more

Webinars

Get hooked on automated buffer exchange with Lil’ Tuna

Brian Haldeman, PhD, Product Manager, Unchained Labs

App Notes

Meet Lil’ Tuna: Automated plate-based benchtop buffer exchange

Technology

Ultrafiltration & Diafiltration (UF/DF)

Specifications

Application
Buffer exchange volume rangeUna: 0.45-8 mL
Unfilter 24: 0.45-8 mL
Unfilter 96: 100-450 μL
FormulationsUp to 6 formulations in parallel
SamplesUna: up to 6 samples in parallel
Unfilter 24: up to 24 samples in parallel
Unfilter 96: up to 96 samples in parallel
Sample types Antibodies and other proteins, nucleic acids, viral vectors
Exchange time at full volume (96%, at 10 mg/mL IgG) Una: 4.5 hours*
Unfilter 24: 4.5 hours*
Unfilter 96: 3 hours*
Protein concentration (range)Up to 200 mg/mL*
Dispense precision<300 μL: ≤3 μL
0.3–8 mL: ≤1%
Target concentration accuracy±10%*
Sample recovery≥96%*
System
Volume measurementUltrasonic sensor
Exchange pressures15-60 psi
Operating temperatureRoom temperature
Buffer exchange orbital mixingUnfilter 24 and Una: optimized at 700 rpm
Unfilter 96: optimized at 875 rpm
Duty cycle programmable
Physical36.8 cm W x 57.8 cm D x 37.2 cm H; 38.4 kg (instrument)
ElectricalVoltage 100-260 VAC, 50-60 Hz
Nitrogen or CDA requirementPressure 0.55–0.9 MPa (80–130 psi)
Consumables
Una10, 30, and 100 kDa, regenerated cellulose
30 and 100 kDa polyethersulfone
Unfilter 2410, 30, and 100 kDa, regenerated cellulose
Unfilter 963, 10, 30, and 100 kDa, regenerated cellulose
*Sample and formulation dependent.

Want a quote?